47
IQAN-MC3 Technical Overview
Appendix A
Instruction book, IQAN-MC3
System
T
A
= -40 to +85 °C (unless otherwise specified)
Weight
1.1 kg
Ambient temperature,
T
ROC
-40 to +85 °C
Voltage supply on +BAT,
V
BAT
9 to 32 Vdc
Current supply
V
BAT
=14V
V
BAT
=28V
typ. 250 mA
typ. 170 mA
Start up time
typ. 1000 ms (with a small application)
System cycle time,
T
SC
10 to 100 ms
Application flash memory
1.5 MB
Application RAM memory
1.5 MB
Data log memory
typ. 80,000 records
Safety integrity level
System capability
Element complexity
PFH
D
SFF
HFT
Diagnostic test interval
Lifetime
Periodic proof test
up to SIL2
SC2
Type B
2 x 10
-8
99%
0
100 ms @ T
SC
<75 ms
40,000 hours
No
Sensor supply, VREF
Number of VREF
2
Output voltage
5 V ±150 mV, -40 to 85 °C
Output voltage temperature drift
0.25 mV/°C, -40 to 85 °C
Maximum load current
140 mA on each VREF
Protection
overload, SCB, SCG
Diagnostics
over/under voltage
Under/over voltage threshold
±150 mV from nominal value
Signal input, VIN
Number of VIN
16
VIN full scale
5000 mV ±100 mV
VIN resolution
12 bits = 1.22 mV
Input impedance
36 kohm in parallel with 10 nF
Accuracy
with external sensor supply
with VREF sensor supply
±(0.8 % + 5 mV)
±(0.2 % + 5 mV)
Sample rate
same as system cycle time
Maximum continuous voltage
5.5 V
Protection
SCB, SCG
Diagnostics
ADC scale error <3 %
Summary of Contents for iqan-mc3
Page 1: ...IQAN MC3 Instruction book Publ no HY33 8001 IB UK Edition 2016 05 16...
Page 18: ...15 Markings Approvals 4 Safety Instruction book IQAN MC3 Markings Approvals...
Page 19: ...16 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 20: ...17 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 21: ...18 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 22: ...19 Markings Approvals 4 Safety Instruction book IQAN MC3...