56
Failure modes
Appendix B
Instruction book, IQAN-MC3
On - active CRET
On - passive CRET
Failure mode
Detected
Comment
COUT open
•
CRET open
•
COUT short circuit to CRET (active)
•
COUT short circuit to CRET (passive)
No influence on function in this state.
COUT short circuit to +BAT
•
Reverse feed *.
No influence on function in this state.
COUT short circuit to -BAT
•
CRET (active) short circuit to +BAT
•
Detection is limited to this output.
Reverse feed * is not detected.
CRET (active) short circuit to -BAT
•
CRET+ short-circuit to CRET-
•
COUT short-circuit to 2
nd
COUT
•
COUT short-circuit to 2
nd
DOUT
•
COUT short circuit to 2
nd
CRET/DRET
(active)
No influence on COUT (error detected
on 2
nd
COUT/DOUT).
COUT short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
CRET short circuit to 2
nd
CRET (active)
•
CRET short circuit to 2
nd
CRET
(passive)
No influence on COUT (error detected
on 2
nd
COUT/DOUT).
Insufficient voltage on +BAT
current saturated 75% to 100%.
Insufficient voltage on +BAT, current
saturated < 75%
•
Failure mode
Detected
Comment
CRET open
•
CRET short circuit to +BAT
Reverse feed *.
No influence on function in this state.
CRET short circuit to -BAT
•
CRET short circuit to 2
nd
CRET
(passive)
No influence on function in this state.
Summary of Contents for iqan-mc3
Page 1: ...IQAN MC3 Instruction book Publ no HY33 8001 IB UK Edition 2016 05 16...
Page 18: ...15 Markings Approvals 4 Safety Instruction book IQAN MC3 Markings Approvals...
Page 19: ...16 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 20: ...17 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 21: ...18 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 22: ...19 Markings Approvals 4 Safety Instruction book IQAN MC3...