60
Failure modes
Appendix B
Instruction book, IQAN-MC3
On - under current detection disabled
Failure mode
Detected
Comment
DOUT open
No current through load.
DRET open
No current through load.
DOUT short circuit to +BAT
Reverse feed *.
No influence on function in this state.
DOUT short circuit to -BAT
Thermal shutdown, or fuse blows.
DOUT short circuit to DRET
Thermal shutdown, or fuse blows.
DOUT over current
•
DRET short circuit to +BAT
•
Detected, or fuse blows.
Detection is limited to this output.
Reverse feed * is not detected.
DRET short circuit to -BAT
No influence on function in this state.
DOUT short-circuit to 2
nd
DOUT
No influence on function in this state.
DOUT short-circuit to 2
nd
COUT
No influence on function in this state.
DOUT short circuit to 2
nd
CRET (active)
No influence on DOUT (error detected
on 2
nd
COUT).
DOUT short circuit to 2
nd
DRET (active)
Thermal shutdown, or fuse blows.
DOUT short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
DRET short circuit to 2
nd
DRET (active)
No influence on function in this state.
DRET short circuit to 2
nd
CRET (active)
No influence on DOUT (error detected
on 2
nd
COUT).
DRET short circuit to 2
nd
CRET/DRET
(passive)
No influence on function in this state.
Insufficient voltage on +BAT
Under current
Summary of Contents for iqan-mc3
Page 1: ...IQAN MC3 Instruction book Publ no HY33 8001 IB UK Edition 2016 05 16...
Page 18: ...15 Markings Approvals 4 Safety Instruction book IQAN MC3 Markings Approvals...
Page 19: ...16 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 20: ...17 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 21: ...18 Markings Approvals 4 Safety Instruction book IQAN MC3...
Page 22: ...19 Markings Approvals 4 Safety Instruction book IQAN MC3...