Mounting
HLR Mounting Instruction
26
192-510201N1 HLR 2019-04
Place the connection shaft (see Figure 4, Pos.6) on the shaft trunions and
mediate between the linear axes. Check distance between deflection stations and
connection shaft on both sides (see Table 2, Figure 4, measurement L03).
Place tension halves of the connection shaft (please refer to Figure 4, Pos. 5) and
slightly tighten with the clamping screws (please refer to Figure 4, Pos. 8).
Tigthen clamping screws in such a way that an equal-sized slot between coupling
halves and tension halves turns up.
Alternately tighten the clamping screws to the respective tightening torque
(please refer to Table 3).
HLR070
HLR080
Tightening torque clamp collar (please refer to Figure 4, Pos. 3)
Screw type [ISO 4762]
-
M5 x 14 – 10.9
M6 x 20 - 10.9
Tightening torque
[Nm]
6.0
15.0
Tightening torque connection shaft (please refer to Figure 4, Pos. 8
Screw type [ISO 4762]
M6 x16 – A2-70
Tightening torque
[Nm]
7.4
Table 3: Tightening torques and screws of the connection shaft
3.4
Correct position of loads on the carriage.
Standar carriages of HLE linear actuators have various mounting threads for the
connection of loads, cross beams or Z-axes.
Existing centering sleeves integrated into the carriage can be used to align the
load.
Position of mounting threads and centering sleeves and depth see dimensions (see
page 17).
All loads mounted to the carriage must be securely safed against shifing and
sliding. Not sufficiently fastened linear actuators may shift, slide and may cause
considerable damage and injuries.
The torque moments mentioned below are mandatory.
The thread depth of the mounting bore in the carriage may not be exceeded.
Failure to comply with this may result in a breakthrough and damage to the
carriage.
If the specified tightening torques are exceeded, there is a risk of damage to the
threads.
HLR070 & HLR080
Present screw-in depth*
HLR070 / HLR080
Recommended screw-in
depth*
Tightening torque**
Thread size
[mm]
[mm]
[Nm]
M4
4.0/6.0
3.5
2.5
M5
7.5/9.0
6.0
5.0
M6
7.5/9.0
6.0
7.5
Table 4: Anzugsmomente mounting thread of the carriage
* Maximum present thread depth may not be exceeded.
** Recommended tightening torque valid for the recommended srew-in depth. Depending on screw-in depth, application boundary
conditions and tightening/ screwing procedure, the tightening torque may vary and must be defined by the customer in individual cases.
Installation surface requirements of the payload
Flatness of the installation surface of the payload ≤ 0.05 mm
When the centering sleeves for mounting the load are an obstacle, they can be
carefully pulled out with a pair of needle-nose pliers.
Summary of Contents for HLR070
Page 6: ...Introduction HLR Mounting Instruction 6 192 510201N1 HLR 2019 04 1 3 Mounting explanation ...
Page 14: ...Device description HLR Mounting Instruction 14 192 510201N1 HLR 2019 04 ...
Page 15: ...Parker EME Conditions of utilization 192 510201N1 HLR 2019 04 15 ...
Page 16: ...Device description HLR Mounting Instruction 16 192 510201N1 HLR 2019 04 2 1 Technical data ...
Page 17: ...Parker EME Dimensions 192 510201N1 HLR 2019 04 17 2 2 Dimensions ...
Page 18: ...Device description HLR Mounting Instruction 18 192 510201N1 HLR 2019 04 ...
Page 19: ...Parker EME Dimensions 192 510201N1 HLR 2019 04 19 ...
Page 54: ...Index HLR Mounting Instruction 54 192 510201N1 HLR 2019 04 ...
Page 55: ...Parker EME Spare and Wear Parts 192 510201N1 HLR 2019 04 55 ...
Page 56: ...Index HLR Mounting Instruction 56 192 510201N1 HLR 2019 04 ...