Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois
www.parker.com
/cylinder
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Catalog HY08-4005-M3
94
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
IN 1
INPUT 1 BREAK
I/O TRIPS:: INPUT 1
BREAK has gone True
♦
Check configuration to determine source of signal
IN 2
INPUT 2 BREAK I/O TRIPS:: INPUT 2
BREAK has gone True
♦
Check configuration to determine source of signal
STLL
MOTOR STALLED The motor has stalled (not
rotating)
♦
Motor loading too great
♦
Current limit level is set too low
♦
Stall trip duration is set too low
♦
Fixed or auto boost levels are set too high
IT
INVERSE TIME
♦
The inverse time current limit is active: motor loading
is too great; fixed or auto boost levels are too high
(Full Load Current = 150% for 60 seconds)
DB R
BRAKE RESISTOR External dynamic braking
resistor has been overloaded
♦
Trying to decelerate a large inertia load too quickly or
too often
DB S
BRAKE SWITCH Internal dynamic braking
switch has been overloaded
♦
Trying to decelerate a large inertia load too quickly or
too often
96
w
ww
ww
w..ppaarrkkeerr..ccoom
m/
cylinder