Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
ATND
MOTR STALLED
ERR
♦
The motor must be able to rotate during Autotune
ATNE
AT TORQ LIM ERR
♦
The motor is in torque limit during Autotune
ECAL
absolute position
FBK ENCODR CAL The drive has fail ed to set
♦
Check the encoder supports absolute position, and
that the encoder is wired correctly.
GEAR
OUTPUT GBX
ERROR
♦
A non-unity output gearbox is not supported if the
encoder direction is reversed.
APP
APP HALTED
♦
The application has been halted by the DSE
Configuration Tool
AERR
APP ERROR
♦
The application has ceased execution due to an error
FERR
FIRMWARE ERROR
♦
The firmware in the drive has stopped executing