Operational Modes
S
Sttoopp oonn P
Poossiittiioonn VVaalluuee
Expandable feature for use with Run and Jog mode is the Stop on Position macro built
into the drive. It requires a Position Feedback device should be ordered with the HAS
unit. An external device may also be used.
Stop on Position is enabled through keypad commands and is available with both Jog
and Run modes.
M
Maaccrroo D
Deessccrriippttiioonn::
Macro is enabled from the Stop On Position bit set on the keypad.
With proper setup, electronically adjustable window of stroke can be defined. User can
define units, typically inch units are used, with a maximum value of 600.00". Resolution
of High and Low limit is 0.00 units.
When HAS Unit measured positional value is greater than the High Limit value, the HAS
Unit will decelerate and prevent forward motion.
When HAS Unit measured positional value is less than than the Low Limit value, the HAS
Unit will decelerate and prevent reverse motion.
Position Feedback type is limited to 0-10V analog style units.
Position Feedback can be continuously monitored from the Position output register
located on the Keypad.