Resolver Card
S
Sppeecciiffiiccaattiioonnss –– R
Reessoollvveerr IInntteerrffaaccee ((88990022//R
RE
E aanndd
88990022//R
RR
R))
8902/RE:
Up to 50,000RPM (with 2 pole
resolver ) 8902/RR:
Up to 30,000RPM (with 2 pole
resolver ) 7Vrms, 8kHz
70mA rms
±
12V peak
Maximum Speed
Carrier Output Signal
Maximum Carrier
Supply Maximum Input
Voltage Accuracy
Resolution
Inputs
Isolation
< 5 minutes
Equivalent to 16 bits per electrical
revolution of resolver
Differential inputs, Zin ~2 kΩ
Maximum input voltage : 12Vpeak
None
S
Sppeecciiffiiccaattiioonnss –– E
Em
muullaatteedd E
Ennccooddeerr ((88990022//R
RR
R oonnllyy))
Signal amplitude
Outputs
Signal nomenclature
Number of lines per
revolution Isolation
Compatible with RS422 and RS485
3 Differential pairs
A and B quadrature
Z index pulse
1024
Outputs are isolated from drive electronics
W
WAAR
RN
NIIN
NG
G:: This product can expose you to chemicals including LLeeaadd aanndd LLeeaadd C
Coom
mppoouunnddss which are known to the State of
P
PR
RO
OP
P 6655 W
WA
AR
RN
NIIN
NG
G
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
P
Paarrkkeerr H
Haannnniiffiinn C
Coorrppoorraattiioonn
Cylinder Division
Des Plaines, Illinois
109
w
ww
ww
w..ppaarrkkeerr..ccoom
m/