Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois
www.parker.com
/cylinder
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Catalog HY08-4005-M3
102
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
RSLV RESOLVER ERROR See function block description
♦
Resolver disconnected
♦
Resolver incorrectly wired
♦
Resolver not compatible with resolver feedback
option board
♦
Resolver length cable too long
♦
Incorrect Resolver Function Block settings
MI2T
I2T MOTOR TRIP
See function block description
♦
Motor is undersized
STO
SAFE TORQUE OFF -
♦
The safe torque off feature has been activated. See
Chapter 6, STO Trip Annunciation.
DCFG DRIVE CONFIG ERR Drive configuration error
♦
The configuration defined in DRIVE CONFIG
doesn't match the actual drive configuration.
CT1
Reservoir Over T Reservoir Over Temp
CT2
Low Oil Levl
Oil Level Low
♦
HAS Reservoir exceed 158F and Trip on Temp set in
config
♦
HAS Reservoir level low and Trip on Low Level