Parker Hannifin Corporation
Cylinder Division
Des Plaines, Illinois
www.parker.com
/cylinder
Hydraulic and Electrohydraulic Actuators
HAS Series Analog Drives Manual
Catalog HY08-4005-M3
104
WARNING:
This product can expose you to chemicals including
Lead and Lead Compounds
which are known to the State of
California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
PROP 65 WARNING
Trip Table
66551111
K
Keeyyppaadd
D
Diissppllaayy
66990011
K
Keeyyppaadd
D
Diissppllaayy
D
Deessccrriippttiioonn
P
Poossssiibbllee R
Reeaassoonn ffoorr TTrriipp
T 6
24V FAILURE
The 24V customer output
has fallen below 17V
Refer to Parker Hannifin technical support
T 4
VOLTS SEL SWITCH
Failure to read
voltage
May be caused by excessive loading on ANOUT
PHAS
PHASE LOSS
s
elector
switch
Input phase missing
CHRG
CHARGING
Failed to charge DC link
Excessive capacitance on DC
link Short circuit on DC link
DCRP
VDC RIPPLE
Excessive DC link ripple Driving a reciprocating load
AOUT
ANOUT FAULT
Overload on analog output
VOLT
VOLTS SELECTION
Invalid position on
volts selector switch
ENCI
ENC NEEDS INIT
PMAC motor used with
a relative encoder –
Needs to run init once
per power cycle
Relative encoder needs to be aligned with the
motor back EMF. Use MOT POLARISATION
feature to align