Chapter 1. Installation
11
Electrical Connections
To install the ZETA6xxx so that it is LVD compliant, refer also to the supplemental
instructions in Appendix C. Appendix D provides guidelines on how to install the
ZETA6xxx in a manner most likely to minimize the ZETA6xxx’s emissions and to
maximize the ZETA6xxx’s immunity to externally generated electromagnetic
interference.
Grounding System
Pulse Cut-Off (P-CUT) Emergency Stop Switch
CAUTION
:
You must select either the on-board
+5V
terminal or an external power supply to power the
AUX-P
pull-up resistor (for the
P-CUT
,
HOM
,
NEG
,
POS
,
TRG-A
, and
TRG-B
inputs).
Connecting
AUX-P
to the
+5V
terminal and an external supply will
damage the ZETA6xxx
.
(The same rule applies to the
IN-P
and
OUT-P
terminals, see page 20.)