Chapter 1. Installation
23
Connection to a Combination of Sinking & Sourcing Inputs
Connection to an Inductive Load (active low)
PROGRAMMING TIP
Connecting to an active-
high sinking input? Set
the output’s active level to
high with the OUTLVL
command (1 = active high).
Connecting to an active-
low sourcing input? Set
the output’s active level to
low with the OUTLVL
command (0 = active low).
Thus, when the ZETA6xxx’s
output is activated, current
will flow through the
attached input and the
TOUT status command will
report a “1” (indicates that
the output is active),
regardless of the type of
input that is connected.
Details on setting the active
level and checking the
output status are provided in
the 6000 Series
Programmer’s Guide. Refer
also to the OUTLVL and
TOUT command
descriptions in the 6000
Series Software Reference.