6 Troubleshooting
In the unlikely event that a problem occurs on the equipment, this troubleshooting guide can be used to identify the probable cause and remedy.
6.1 Dewpoint Failure
A dewpoint failure will result in there being water in the downstream piping and equipment.
Troubleshooting should only be attempted by competent personnel. All major repair, and calibration work should be
undertaken by a Parker trained, qualified and approved engineer.
Possible Cause
Action Required
The inlet parameters have changed.
If the inlet flow-rate or the inlet temperature have increased ensure
that the filters and dryer are re-sized accordingly.
If the inlet pressure has changed ensure that the filters and dryer
are re-sized accordingly.
The condensate is not being drained.
Verify that all condensate drains are functioning correctly.
Check that the drain hoses are free from kinks and obstructions.
Ensure that the isolation valves on the drains are fully open.
The compressor is not functioning correctly.
Check the documentation supplied by the compressor manufacturer
for troubleshooting guidance.
The compressor capacity has changed.
Ensure that the filters and dryer are sized accordingly.
The after cooler is not functioning correctly.
Test that condensate drain is operating correctly.
Check that the cooling water system is functioning correctly and that
the water temperature is within specification (water cooled systems
only).
Ensure that the after cooler and dust filter (if fitted) are clean (air
cooled systems only).
Ensure that the fan is functioning correctly (air cooled systems only).
There is no wet air receiver fitted within the system.
Install a wet air receiver and drain within the system (if possible).
Ensure there is adequate drainage on the piping prior to the dryer
pre-filtration. A water separator should also be installed before the
dryer pre-filtration to ensure removal of bulk liquid.
Filtration has not been correctly maintained.
If the element and float drain have been installed longer than 12
months ensure that they are both changed.
Verify that the float drain is operating correctly.
The dryer has been by-passed.
If a bypass line has been installed on the system ensure that it is
closed. Use bypass filtration.
The regeneration column pressure within the dryer is greater than
350mbar.
Contact a Parker approved service agent.
There is a fault with the dryer timer.
Contact a Parker approved service agent.
There is a fault with the dryer valves.
Contact a Parker approved service agent.
The desiccant is approaching the end of its useful life.
Contact a Parker approved service agent.
Summary of Contents for CDAS HL 050 Series
Page 2: ......
Page 4: ......
Page 36: ...32 8 Schematics Pneumatic Schematic 008730000 ...
Page 37: ...33 Wiring Diagram 008730002 ...
Page 38: ...34 ...
Page 40: ......
Page 72: ...68 8 Schema Persluchtschema 008730000 ...
Page 73: ...69 Bedradingsdiagram 008730002 ...
Page 74: ...70 ...
Page 76: ......
Page 108: ...104 8 Anschlusspläne Pneumatik Schemazeichnung 008730000 ...
Page 109: ...105 Schaltplan 008730002 ...
Page 110: ...106 ...
Page 112: ......
Page 144: ...140 8 Schéma Schémas pneumatiques 008730000 ...
Page 145: ...141 Schéma de câblage 008730002 ...
Page 146: ...142 ...
Page 148: ......
Page 180: ...176 8 Scheman Pneumatikschema 008730000 ...
Page 181: ...177 Kopplingsschema 008730002 ...
Page 182: ...178 ...
Page 184: ......
Page 216: ...212 8 Skjemaer Pneumatisk skjema 008730000 ...
Page 217: ...213 Koblingsskjema 008730002 ...
Page 218: ...214 ...
Page 220: ......
Page 252: ...248 8 Skema Pneumatisk skema 008730000 ...
Page 253: ...249 Ledningsdiagram 008730002 ...
Page 254: ...250 ...
Page 256: ......
Page 288: ...284 8 Diagramas Diagrama neumático 008730000 ...
Page 289: ...285 Diagramas del cableado 008730002 ...
Page 290: ...286 ...
Page 292: ......
Page 324: ...320 8 Schemi Schema pneumatico 008730000 ...
Page 325: ...321 Schema di cablaggio 008730002 ...
Page 326: ...322 ...
Page 328: ......
Page 360: ...356 8 Schematy Schemat pneumatyczny 008730000 ...
Page 361: ...357 Schemat okablowania 008730002 ...
Page 362: ...358 ...
Page 364: ......
Page 374: ...370 2 7 Parker domnick hunter 2 7 1 2 7 2 A B C ...
Page 379: ...375 3 3 3 3 1 3 3 2 500 20 750 29 5 3 4 3 4 1 ...
Page 385: ...381 3 5 8 CDAS OFAS CDAS OFAS DIP 008730000 8 _ 3 6 1 2 3 4 DIP 1 DIL 7 ...
Page 387: ...383 4 1 2 _ _ _ _ ERR _ ECO ECO ECO MODBUS ECO ...
Page 388: ...384 4 2 1 2 3 4 5 4 3 1 2 3 _ MODBUS ...
Page 389: ...385 5 5 1 _ _ 3 _ 6 _ 12 _ 60 _ POWER ON STATUS FAULT OFAS ...
Page 393: ...389 6 6 1 _ _ _ Parker 12 350 Parker Parker Parker Parker ...
Page 394: ...390 6 2 6 3 _ 12 Parker ...
Page 396: ...392 8 008730000 ...
Page 397: ...393 008730002 ...