16
3.4.2 Securing the Dryer
Mounting holes are provided in the feet of the dryer. Once the dryer has been
positioned in its final location ensure that it is securely fixed in place using
M15 fixing bolts.
3.4.3 Attach the Exhaust Silencer
The dryer is supplied with an exhaust silencer. If the dryer is to be located in a
noise sensitive area, exhaust air can also be remotely piped away. If the
exhaust is to be piped away then a minimum pipe size of 50mm (2 ins) should
be used initially, expanding to larger diameter the longer the piping run
becomes. As a rule of thumb a minimum bend radius of four times the radius
of the pipe should be employed. Failure to pipe away correctly results in back
pressure (indicated by a minimal pressure on the off-line pressure gauge)
which prevents full regeneration of the off-line bed and results in loss of
dewpoint.
3.4.4 Purge Settings
The nominal flow rates for CDAS HL / OFAS HL dryers are based upon an
operating pressure of 7 bar g (102 psi g). If the minimum operating pressure of
the site is higher or lower than the nominal pressure, the purge setting must
be reset for the minimum pressure into the dryer. Failure to correctly set purge
during commissioning will seriously affect dryer performance, operational
costs and will invalidate warranty
Before setting the purge, fully close the valve and ensure that the screwdriver
slot is aligned with the number 12 on the purge dial.
Purge settings comprise of a number of full turns of the adjusting screw plus a
partial turn to the numbered position on the dial. See the table below for the
correct settings.
Example: To set the purge for a CDAS HL 050 operating at 6 Bar g.
Fully close the valve
Turn the screw anti-clockwise 5 full turns
Turn the screw a further partial turn until the screwdriver slot is
half way between No. 1 and No. 2.
Unless otherwise specified, all dryers are factory set at 6 Bar g.
Pressure (Bar g)
CDAS /
OFAS
Purge Flow
Dial
Setting
4
5
6
7
8
9
10
11
12
13
14
15
16
(m3/hr)
(L/m)
HL 050
11
183
Full Turns
6
5
5
4
4
4
3
3
3
3
3
3
3
+ dial No.
6
10
1.5
8.5
4.5
1.5
11.5
9.5
7.5
5.5
4.5
3.5
2.5
HL 055
14
233
Full Turns
6
6
6
5
5
4
4
4
4
3
3
3
3
+ dial No.
11
7.5
1.5
7
2
10
6.5
4
1
11
9.5
8
7
HL 060
18
300
Full Turns
7
7
6
6
6
5
5
5
4
4
4
4
4
+ dial No.
4.5
0
9
6
2
8.5
4.5
0.5
9
6.5
4.5
2.5
1.5
HL 065
22
367
Full Turns
7
7
7
6
6
6
6
5
5
5
4
4
4
+ dial No.
8.5
4.5
1.5
10.5
8
5.5
2
9.5
5
2
11
8.5
7
HL 070
30
500
Full Turns
8
7
7
7
7
7
6
6
6
6
6
5
5
+ dial No.
4
11.5
8
5
2
0
10
8.5
7
5
1.5
10
8
HL 075
37
617
Full Turns
8
8
8
7
7
7
7
7
6
6
6
6
6
+ dial No.
9.5
4
0.5
9.5
7
4.5
3
1
11
9.5
8
7
5
HL 080
44
733
Full Turns
9
8
8
8
7
7
7
7
7
7
7
6
6
+ dial No.
3
9
4.5
1.5
10.5
8
6
4.5
3
1.5
0
10.5
9
HL 085
60
1000
Full Turns
10
9
9
8
8
8
8
7
7
7
7
7
7
+ dial No.
3
7
2
9
6
3
1
11
9
7.5
6.5
5
3.5
3
1
2
1
M15 fixing bolts (not supplied)
2
Exhaust Silencer
3
Adjustable Purge Dial
Summary of Contents for CDAS HL 050 Series
Page 2: ......
Page 4: ......
Page 36: ...32 8 Schematics Pneumatic Schematic 008730000 ...
Page 37: ...33 Wiring Diagram 008730002 ...
Page 38: ...34 ...
Page 40: ......
Page 72: ...68 8 Schema Persluchtschema 008730000 ...
Page 73: ...69 Bedradingsdiagram 008730002 ...
Page 74: ...70 ...
Page 76: ......
Page 108: ...104 8 Anschlusspläne Pneumatik Schemazeichnung 008730000 ...
Page 109: ...105 Schaltplan 008730002 ...
Page 110: ...106 ...
Page 112: ......
Page 144: ...140 8 Schéma Schémas pneumatiques 008730000 ...
Page 145: ...141 Schéma de câblage 008730002 ...
Page 146: ...142 ...
Page 148: ......
Page 180: ...176 8 Scheman Pneumatikschema 008730000 ...
Page 181: ...177 Kopplingsschema 008730002 ...
Page 182: ...178 ...
Page 184: ......
Page 216: ...212 8 Skjemaer Pneumatisk skjema 008730000 ...
Page 217: ...213 Koblingsskjema 008730002 ...
Page 218: ...214 ...
Page 220: ......
Page 252: ...248 8 Skema Pneumatisk skema 008730000 ...
Page 253: ...249 Ledningsdiagram 008730002 ...
Page 254: ...250 ...
Page 256: ......
Page 288: ...284 8 Diagramas Diagrama neumático 008730000 ...
Page 289: ...285 Diagramas del cableado 008730002 ...
Page 290: ...286 ...
Page 292: ......
Page 324: ...320 8 Schemi Schema pneumatico 008730000 ...
Page 325: ...321 Schema di cablaggio 008730002 ...
Page 326: ...322 ...
Page 328: ......
Page 360: ...356 8 Schematy Schemat pneumatyczny 008730000 ...
Page 361: ...357 Schemat okablowania 008730002 ...
Page 362: ...358 ...
Page 364: ......
Page 374: ...370 2 7 Parker domnick hunter 2 7 1 2 7 2 A B C ...
Page 379: ...375 3 3 3 3 1 3 3 2 500 20 750 29 5 3 4 3 4 1 ...
Page 385: ...381 3 5 8 CDAS OFAS CDAS OFAS DIP 008730000 8 _ 3 6 1 2 3 4 DIP 1 DIL 7 ...
Page 387: ...383 4 1 2 _ _ _ _ ERR _ ECO ECO ECO MODBUS ECO ...
Page 388: ...384 4 2 1 2 3 4 5 4 3 1 2 3 _ MODBUS ...
Page 389: ...385 5 5 1 _ _ 3 _ 6 _ 12 _ 60 _ POWER ON STATUS FAULT OFAS ...
Page 393: ...389 6 6 1 _ _ _ Parker 12 350 Parker Parker Parker Parker ...
Page 394: ...390 6 2 6 3 _ 12 Parker ...
Page 396: ...392 8 008730000 ...
Page 397: ...393 008730002 ...