NFF380---4500
34
Tab. 1 --- Operational characteristics
FILTER ELEMENT PRESSURE DROP (barg)
GRADE
WORKING RANGE
new
nominal
new
oil saturated
recommended
maximum
D
1.5---65
_
C
0.07
0.14
0.35
Q
1.5---65
_
C
0.07
0.14
0.35
P
1.5---65
_
C
0.07
0.14
0.35
S
1.5---65
_
C
0.10
0.20
0.35
C
1.5---30
_
C
0.07
N.A.
Substitute element
before oil saturation
(~ 1000h at 25
˚
C).