background image

ENGINEERING STANDARDS

Rosedale Products, Inc.

IOM

Issue Date: 31JUL02

3730 West Liberty Road

7_3_5 Model LCO 6.wpd

Revision: A

Ann Arbor, MI 48103

n:\iom\

Revision Date: 30May2003

Specification No.

7.3.5

PAGE:  1 of 6 

INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Rosedale Engineering Standards are the property of Rosedale Products, Inc.  A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

Products, Inc.) to any individual or firm beyond the intended recipient firm or individual.  Firms of individuals acting contrary to the above may be subject to suit, ineligibility for continued or

future employment, or removal from Rosedale’s "Approved Manufacturers and Specialty Contractors List".

INSTALLATION, OPERATION AND

MAINTENANCE MANUAL

ROSEDALE PRODUCTS, INC.

MODEL

 

LCO-6

125 PSIG RATED FILTER UNIT

Table of Contents

I.

INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

II.

OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

III.

SPARE PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

IV.

SPARE PARTS DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Summary of Contents for LCO-6

Page 1: ...hall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Manufacturers and Specialty Contractors List INSTALLATION OPERATION AND MAINTENANCE MANUA...

Page 2: ... level There are two 1 4 NPT ports on the shell of your Model LCO 6 Filter These ports can remain plugged or used for pressure gauges vents or special fitting as your application requires Some installations require electrical grounding of all equipment be sure to provide adequate grounding where necessary After completing installation be sure to double check connections for integrity Your Model LC...

Page 3: ...mplete opening of inlet service line until desired flow rate is reached Once the desired service flow has been established the filter will operate efficiently until dirty However under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained Operating the filter unit with a high differential may cause filter bags to rupture and or cause damage to filter system ...

Page 4: ...essary and make sure it is properly seated 10 Reposition cover onto housing install T bolt clamp and securely tighten to ensure a leak proof seal between the cover housing body Your Rosedale Model LCO 6 Filter unit is now ready for operation Refer to filter system start up procedure III SPARE PARTS LIST Your Rosedale Model LCO 6 Filter unit will give many years of reliable service provided periodi...

Page 5: ...andards are the property of Rosedale Products Inc A Rosedale standard or copy thereof shall not be distributed except with express approval of Rosedale Products Inc to any individual or firm beyond the intended recipient firm or individual Firms of individuals acting contrary to the above may be subject to suit ineligibility for continued or future employment or removal from Rosedale s Approved Ma...

Page 6: ... rosedaleproducts com Important Notice Warranty In the event any Rosedale Products Inc filtration product is found to be defective in material workmanship or not in conformance with any express warranty for a specific purpose Rosedale s only obligation and your exclusive remedy shall be to repair replace or refund the purchase price of such parts or products upon timely notification thereof and su...