J. Technical Data and Symbols
21 Questions about eRapid? Call 1-866-335-6943
Weight: Controller and Handset .................................................................................................................................. 6 oz. (170 g)
Weight: Controller, Handset, and Batteries ................................................................................................ approx. 9.5 oz. (270 g)
Dimensions: Handset ................................................................................................... 1.93 x 2.5 x 5.5 inches (4.9 X 6.4 x 14 cm)
Electrical Requirements ................................................................................................................................. 100 - 240 V, 50/60 Hz
Power Wattage ....................................................................................................................................2.0 Watts under normal load
Minimum Fill .............................................................................................................................................................................2 mL
Maximum Volume Fill ...............................................................................................................................................................6 mL
Residual volume remaining after nebulization ................................................................................................................ about 1 mL
Operation/Storage
Controlled Room Temperature ................................................................................................................. 41 - 104 °F (5 - 40°C)
Batteries
High quality alkaline or lithium .............................................................................................................................................. 1.5V
Battery Operation… ............................................................................................ approximately 2 hours of continuous treatment
Device Classification According to IEC 60601-1
Type of electric shock protection (AC Power Supply) ......................................................................................... Protection Class II
Degree of protection from electric shock of part used (nebulizer) ...................................................................................... Type BF
Degree of protection against water ingress per IEC 60529 IP rating (nebulizer) ..................................................................... IP 21
Degree of protection when in the presence of flammable mixtures ............................................................................ No protection
Continuous operation ............................................................................................................................................. Operating mode
Please follow the instructions for use
Caution: Read all warnings and precautions in
instructions for use
Part number of the device
Protection class II appliance
Serial number of the device
CE marking: This product is compliant with the
requirements set forth in 93/42/EEC (Medical
Devices) and 2011/65/EU (RoHS)
Direct current
Do not dispose in domestic waste
Indoor use only
Manufacturer
Protection class of the part used: Type BF
Certification Mark
IP21
Protected from condensation
Technical Data