3. Installing the CPX-1000
1000-A2-GN22-00
3-26
February 2003
Attach the T-1/
DS-1 Cables
The CPX connects to host Class 5 switches via multiple T1/DS-1
spans. Each T-1 module in the CPX includes a corresponding T1
transition module that is accessible from the rear of the shelf.
Attaching Cables
to Octal T1
Modules
Connect the host switch T1 cables to the CPX:
Step 1
Following the installation engineering and provisioning
documentation, map the T1/DS-1 connections from the host switch
to T1/DS-1 groups.
Each T1 connection is assigned a T1/DS-1 group number and an
individual connection number, such as 1-1. T-1 #1 must connect to
T1/DS-1 #1 at the Class 5 switch, etc. A T1/DS-1 interface group is
the logical administrator of the T1s. The minimum number
required for an interface group is 2.
Step 2
Connect the T1/DS-1 spans to the T-1 transition modules in the
back of the CPX shelf.
Note
T1 cables for the Octal T1 module require RJ-48C plugs
on the CPX end for these connections. To facilitate the
connections, label each cable by its destination port at
the host Class 5 switch.
Note
T1 jacks are numbered 1–8 or 1–12 (#1 is located at the bottom).
Summary of Contents for Jetstream CPX-1000
Page 14: ...Preface 1000 A2 GN22 00 x February 2003...
Page 24: ...1 Voice over Broadband Networking 1000 A2 GN22 00 1 10 February 2003...
Page 64: ...2 CPX 1000 Voice Services Platform Description 1000 A2 GN22 00 2 40 February 2003...
Page 100: ...3 Installing the CPX 1000 1000 A2 GN22 00 3 36 February 2003...
Page 128: ...5 Repair Procedures 1000 A2 GN22 00 5 14 February 2003...
Page 156: ...D Specifications 1000 A2 GN22 00 D 8 February 2003...