February 2003
3-17
1000-A2-GN22-00
3. Installing the CPX-1000
To connect plant battery power and ground to the CPX, follow
these steps:
Step 1
Terminate a #6 AWG frame ground wire in an LCC or LCD
compression lug (with two #10 screw holes).
Step 2
Using two 10-32
×
¼-inch machine screws, attach a frame grounding
cable to the two rear panel ground points. Attach the other end of
this grounding cable to rack ground.
Electro-Static Caution
Use a wrist grounding strap, attached to the grounding jack
on the CPX enclosure, when working with the system. ESD
can seriously damage the printed circuit card assemblies
and solid-state components inside the CPX.
Note
Do not apply power to the CPX until you finish all
installation tasks. Ensure that the shelf circuit breaker is
set to OFF/0.
0069
16
15
14
13
12
11
7
9
6
8
10
5
4
3
2
1
DC -48V
DC -48V
RTN
DC -48V
DC -48V
RTN
To
Plant Battery "A"
-48V R
T
N
-48V
To
Plant Battery "B"
-48V
-48V R
T
N
Plant
Battery A
Barrier Strip
Frame
Ground
Points
(requires
10-32 x 1/4"
screws)
Circuit
Breaker
Plant
Battery B
Barrier Strip
Open Protective Guards
Summary of Contents for Jetstream CPX-1000
Page 14: ...Preface 1000 A2 GN22 00 x February 2003...
Page 24: ...1 Voice over Broadband Networking 1000 A2 GN22 00 1 10 February 2003...
Page 64: ...2 CPX 1000 Voice Services Platform Description 1000 A2 GN22 00 2 40 February 2003...
Page 100: ...3 Installing the CPX 1000 1000 A2 GN22 00 3 36 February 2003...
Page 128: ...5 Repair Procedures 1000 A2 GN22 00 5 14 February 2003...
Page 156: ...D Specifications 1000 A2 GN22 00 D 8 February 2003...