February 2003
D-5
1000-A2-GN22-00
D. Specifications
Table D–4. CPX-1000 Electronic Specifications
Parameter
Specification
T1 PTSN Connections
Physical interface
Short-haul 4-wire, twisted pair (ABAM) cable, shielded
Impedance
100
Ω
(nominal)
DS1 max. span length
655 ft.
Line Build Out
0–133 ft., 133–266 ft., 399–533 ft., 533–655 ft. (customer order)
T1 Max span length
0–5000 ft. (NEBS certified)
Termination
RJ-48C plug
Signal amplitude
2.4 to 3.6V (DSX-1)
Rcv Attenuation
<10dB (DSX-1)
Framing
ESF (10 ms maximum)
Line coding
B8ZS
Clock
T1/DS-1 Rcv (defaults to internal if Rcv fails)
STS-1 PSTN Connections
Physical interface
coaxial cable
Impedance
75
Ω
(nominal)
max. length
450 ft.
Line Build Out
0–50 ft., 50–450 ft.
STS-1 Max span length
450 ft
Termination
BNC
Framing
STS-1
Line coding
B3ZS