1. Network Management Specification
84
June 2004
8000-A2-GB30-30
8.1.2.1.16
entPhysicalIsFRU
This object indicates whether or not this physical entity is considered a 'field replaceable
unit' by the vendor. If this object contains the value 'true(1)' then this entPhysicalEntry
identifies a field replaceable unit. For all entPhysicalEntries which represent components
that are permanently contained within a field replaceable unit, the value 'false(2)' should be
returned for this object.
Valid Object Value(s):
The following table shows the entPhysicalIsFRU designated for the entities.
OC3 port
zero-length-string (read-only)
DS3 port
zero-length-string (read-only)
GigE/100BT port
zero-length-string (read-only)
Console port
zero-length-string (read-only)
Ethernet Mgmt port
zero-length-string (read-only)
Temp Sensor
zero-length-string (read-only)
Fan
zero-length-string (read-only)
PowerSupply
zero-length-string (read-only)
Management Plane PLD
zero-length-string (read-only)
Uplink PLD
zero-length-string (read-only)
Table 1-98. entPhysicalIsFRU (1 of 2)
Entity
entPhysicalIsFRU
Chassis
TRUE
Container
TRUE
Module
TRUE
Uplink Module
TRUE
Splitter card
TRUE
DSL Port
FALSE
T1/E1 port
FALSE
OC3 port
FALSE
ds3 port
FALSE
GigE/100BT port
FALSE
Console port
FALSE
Ethernet Mgmt port
FALSE
Temp Sensor
FALSE
Table 1-97. entPhysicalAssetID (2 of 2)
Entity
entPhysicalAssetID