Operation and Maintenance
10-15
9124-A2-GH30-00
June 1999 - Preliminary
Table 10-6.
Health and Status Messages (3 of 6)
Message
What It Indicates
What To Do
LMI Down, frame relay
link
2
The Local Management
Interface is down for the
specified frame relay link.
For the Network interface:
1. If LMI was never up, verify
that the proper time slots
have been configured.
2. If LMI was never up, verify
that the LMI Protocol setting
reflects the LMI type being
used.
3. Verify that Frame Relay
Performance Statistics show
LMI frames being transmitted.
If all of the above have been
verified and the physical link is
not in Alarm, contact network
provider.
For Port-n:
1. Check that the DTE cable is
securely attached at both
ends.
2. Verify that Transmit Clock
Source and Invert Transmit
Clock options are properly
configured.
3. Verify that Frame Relay
Performance Statistics show
LMI frames being received. If
no frames are being received:
– Check the attached device.
– Verify that the LMI Protocol
setting reflects the LMI type
being used.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified by for the network port, Network 1.
– Port-1. The frame relay link associated with the user data port.