Configuration
8-27
9124-A2-GH30-00
June 1999 - Preliminary
Table 8-3.
General System Options (2 of 2)
Primary Clock Source
Possible Settings: Net1, DSX, Internal
Default Setting: Net1
Allows you to select the primary clock source for the unit. The source selected provides
all of the timing within the FrameSaver unit and the clocks for all of the external
interfaces. Failure of the clock specified by this configuration option results in automatic
fallback to the Secondary Clock Source configuration option setting.
NOTE:
For the Primary and Secondary Clock Source options, only Internal can be
selected for both options. All other selections must have different settings
(e.g., if Primary Clock Source is set to Net1, Secondary Clock Source
cannot be set to Net1).
Net1 – The primary clock is derived from the Network1 T1 interface.
DSX – The primary clock is derived from the DSX-T1 interface. This setting only
appears if the DSX-1 interface is installed and enabled (see
Configuring the DSX-1
Interface
, page 8-31).
Internal – The primary clock is the internal clock.
Secondary Clock Source
Possible Settings: Net1, DSX, Internal
Default Setting: Internal
Provides a secondary clock source when the primary clock source fails. The source
selected for this configuration option provides all of the timing within the unit and the
clocks for all of the external interfaces.
The clock source will switch back to primary when the primary clock source returns and
is stable for 10 seconds. If the secondary clock source fails, the clock source will switch
to internal. The clock source will switch back to primary when the primary clock source
returns and is stable for 10 seconds.
NOTE:
For the Primary and Secondary Clock Source options, only Internal can be
selected for both options. All other selections must have different settings
(e.g., if Primary Clock Source is set to Net1, Secondary Clock Source
cannot be set to Net1).
Net1 – The secondary clock is derived from the Network1 T1 interface.
DSX – The secondary clock is derived from the DSX-T1 interface. This setting only
appears if the DSX-1 interface is installed and enabled (see
Configuring the DSX-1
Interface Physical Options
, page 8-31).
Internal – The secondary clock is the internal clock.