Configuration
8-24
9124-A2-GH30-00
June 1999 - Preliminary
Table 8-1.
System Frame Relay and LMI Options (2 of 2)
LMI Clearing Event (N3)
Possible Settings: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10
Default Setting: 1
Configures the LMI-defined N3 parameter which sets the number of error-free messages
that must be received before clearing an error event. Applies to both the user and
network sides of the UNI.
1 – 10 – Specifies the number of error-free messages that must be received (inclusive).
LMI Status Enquiry (N1)
Possible Settings: 1, 2, 3, 4, . . . 255
Default Setting: 6
Configures the LMI-defined N1 parameter which sets the number of status enquiry
polling cycles that the user side of the LMI initiates before a full status enquiry is
initiated. Applies only to the user side of the UNI.
1 – 255 – Specifies the number of status enquiry polling cycles that can be initiated
(inclusive).
LMI Heartbeat (T1)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 10
Configures the LMI-defined T1 parameter which sets the number of seconds between
the initiation of status enquiry messages on the user side of the LMI. Applies only to the
user side of the UNI.
5 – 30 – Specifies the number of seconds between the initiation of status enquiry
messages in increments of 5.
LMI Inbound Heartbeat (T2)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 15
Configures the LMI-defined T2 parameter which sets the number of seconds between
the receipt of status enquiry messages on the network side of the LMI. Applies only to
the network side of the UNI.
5 – 30 – Specifies the number of seconds between the receipt of status enquiry
messages in increments of 5.
LMI N4 Measurement Period (T3)
Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 20
Configures the LMI-defined T3 parameter, which is the interval time (in seconds) that the
Network side of the LMI uses to measure the maximum status enquiry messages
received (N4) from the User side. Applies only when LMI Personality is set to Network
Side of the UNI.
5 – 30 – Specifies the interval of time in increments of 5.