Configuration
8-21
9124-A2-GH30-00
June 1999 - Preliminary
Setting Up for Back-to-Back Operation
Using this special feature, you can set up two FrameSaver units that are
connected back-to-back without frame relay switches between them, as in a test
bench setup.
This configuration is shown in the illustration below.
98-16238
FrameSaver
Unit
Frame
Relay
Router
FrameSaver
Unit
Frame
Relay
Router
T1 Crossover
Cable
Changing Operating Mode
When setting up back-to-back operation:
H
One unit must be configured for Standard operation, which is the setting for
normal operation.
H
The other unit must be configured for Back-to-Back operation so it presents
the network side of the UNI.
Only one of the units will have its operating mode changed.
"
Procedure
To set up back-to-back operation:
1. On the unit to be configured for Back-to-Back operation, manually configure
DLCIs; DLCIs should be configured before connecting the two units.
2. Access the Change Operating Mode screen.
Main Menu
→
Control
→
Change Operating Mode
The Change Operating Mode screen appears, with two modes:
3. Select Back-to-Back Operation, and type y ( Yes) at the Are you sure?
prompt.
4. Press Ctrl-a and Save the change.
"
Procedure
To return the unit to normal operation:
1. Return to the Change Operating Mode screen and switch the Operating
Mode back to Standard.
2. Respond Yes to the prompt and save the change. The units can be
reconnected to a standard frame relay network.