C. Configuration Options
3160-A2-GB21-90
February 2001
C-7
Near-end: Disab
Next Disab Maint Send Both Prev
Near-End Performance Statistics. Specifies whether the DSU/CSU maintains near-end
performance statistics and sends performance report messages (PRMs) for a particular
port.
Disab – Disables near-end performance statistics and does not send PRMs.
Maint – Maintains near-end performance statistics for this port.
Send – Sends PRMs over the port’s EDL every second. Each PRM contains the
performance statistics for the previous 4 seconds.
Both – Maintains near-end performance statistics and sends PRMs over the port’s EDL.
NOTES:
– This configuration option is only available on 2-port and 4-port DSU/CSUs.
– This configuration option is not available if
EDL is disabled.
– If the local DSU/CSU is configured to send near-end performance statistics, then
the remote device must be configured to maintain far-end performance statistics.
Far-end: Disab
Next Disab Maint Prev
Far-End Performance Statistics. Specifies whether to monitor for far-end performance
report messages (PRMs) and maintain far-end performance registers for a particular port.
Disab – Disables far-end performance statistics.
Maint – Monitors the port’s EDL for PRMs and maintains far-end performance statistics.
NOTES:
– This configuration option is only available on 2-port and 4-port DSU/CSUs.
– This configuration option is not available if
EDL is disabled.
– If the local DSU/CSU is configured to maintain far-end performance statistics, then
the remote device must be configured to send near-end performance statistics.
Mgmt Link: Disab
Next Enab Disab Prev
EDL Management Link. Specifies whether the EDL management link is enabled for a
particular port. Selecting Enab allows SNMP or Telnet traffic to flow over the 4 kbps
in-band data link provided by EDL.
Enab – Enables the port’s EDL management link.
Disab – Disables the port’s EDL management link.
NOTES:
– This configuration option is only available on 2-port and 4-port DSU/CSUs.
– This configuration option is not available if
EDL is disabled or the FDL is enabled.
– If the local DSU/CSU’s EDL is enabled, then the remote device’s EDL must also be
enabled.
Table C-2.
Port Configuration Options (5 of 5)
Summary of Contents for 3160-A3
Page 16: ...About This Guide x February 2001 3160 A2 GB21 90...
Page 24: ...1 Introduction 1 8 February 2001 3160 A2 GB21 90...
Page 100: ...3 Operation 3 66 February 2001 3160 A2 GB21 90...
Page 142: ...A Front Panel Menu A 2 February 2001 3160 A2 GB21 90...
Page 198: ...C Configuration Options C 54 February 2001 3160 A2 GB21 90...
Page 246: ...E SNMP MIB Objects E 32 February 2001 3160 A2 GB21 90...
Page 280: ...H Asynchronous Terminal Operation H 24 February 2001 3160 A2 GB21 90...
Page 282: ...I Equipment List I 2 February 2001 3160 A2 GB21 90...