4. Configuration
3150-A2-GB24-10
March 2001
4-3
Changing Configuration Options
The CSU is an intelligent device that displays only valid options for the current
configuration. Therefore, you are only presented with menu choices that are
consistent with the current configuration and operational state of the CSU; invalid
combinations of configuration options do not appear. Be aware that although all
options are shown in this guide, what you see on your CSU varies with your
configuration.
The CSU offers configuration options located in the following memory areas:
Active (Activ). This is the configuration option set currently active for the
CSU. Before a configuration option set becomes active for the CSU, you must
save the set to the Active area. When the CSU is shipped from the factory, the
Active configuration option set is identical to the Factory set. This area can be
written to and controls the current operation of the device.
Customer 1 (Cust1). This is the first of two sets of customer-defined
configuration options. This area can be written to.
Customer 2 (Cust2). This is the second of two sets of customer-defined
configuration options. This area can be written to.
Factory 1 (Fact1). This is a set of configuration options preset at the factory.
This set is determined by what is considered to be the most common
configuration used in the CSU market. Factory 1 options are read-only.
Factory 2 (Fact2). This is a set of configuration options preset at the factory.
This set is determined by what is considered to be the second most common
configuration used in the CSU market. Factory 2 options are read-only.
The configuration options are divided into functional groups.
Appendix C,
Configuration Options
, contains a list of the configuration options and defaults.
These groups are:
DTE Interface Configuration Options
Network Interface Configuration Options
General Configuration Options
User Interface Configuration Options
Alarm Configuration Options
Management Configuration Options
Summary of Contents for 3151
Page 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001 ...
Page 16: ...About This Guide x March 2001 3150 A2 GB24 10 ...
Page 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10 ...
Page 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10 ...
Page 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10 ...
Page 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10 ...
Page 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10 ...
Page 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10 ...
Page 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10 ...
Page 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10 ...
Page 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10 ...
Page 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10 ...