2. Installation
2-4
March 2001
3150-A2-GB24-10
Important Instructions
Read and follow all warning notices and instructions marked on the CSU or
included in this guide.
For a complete listing of the safety instructions, see the
Important Safety
Instructions
at the beginning of this guide.
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
Installation Steps
Procedure
1. Attach the power cord to the rear of the CSU and the other end to a grounded
115 Vac power outlet.
2. Attach the DTE cable (DB15) to the DTE connector on the CSU rear panel.
Then, connect the other end of the cable to the DTE.
3. Attach the 8-pin network cable to the NETWORK connector on the CSU rear
panel. Connect the other end of the cable to the RJ48C jack provided by the
telephone company.
4. If you intend to use front panel emulation or the asynchronous terminal
interface, connect a serial cable from your PC or terminal to the COM port on
the rear panel of the CSU.
5. If you intend to manage the 3150 CSU with SNMP over an Ethernet LAN,
connect the 10BaseT port to your LAN and assign an IP address to the port.
See
Configuring the 10BaseT Port
in Chapter 4,
Configuration
.
6. Power on the CSU to perform the power-on self-test.
7. During the power-on self-test, the FAIL LED flashes, then all LEDs blink twice.
When the test is complete, verify that the CSU is functional by observing that
the OK, NETWORK SIG, and DTE SIG LEDs are lit.
8. Set configuration options as required for your environment. See
Changing
Configuration Options
in Chapter 4,
Configuration
.
!
496-15104
Summary of Contents for 3151
Page 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001 ...
Page 16: ...About This Guide x March 2001 3150 A2 GB24 10 ...
Page 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10 ...
Page 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10 ...
Page 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10 ...
Page 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10 ...
Page 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10 ...
Page 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10 ...
Page 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10 ...
Page 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10 ...
Page 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10 ...
Page 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10 ...