56
Reference & Installation Manual
Timer, all the keypad’s LEDs will be off until either a key is pressed or an access code is entered. When the system exits
Confidential Mode, the keypads will display the system’s status. Confidential Mode is activated by enabling option
[3]
. Option
[4]
regulates whether the keypads will be activated at the touch of a key or only when an access code is entered. Option
[5]
determines the amount of time without action before the system enters Confidential Mode (5 seconds or 2 minutes).
14.8
Installer Function Keys
To access the Installer Function keys, press:
[
ENTER
]+[
INSTALLER
CODE
]+[
MEM
]
=
Test Report:
Send the “Test Report” report code programmed in section
[875]
to the
monitoring station.
[
ENTER
]+[
INSTALLER
CODE
]+[
STAY
]
=
Cancel Communication:
Cancels all communication with WinLoad/BabyWare software or
with the monitoring station until the next reportable event.
[
ENTER
]+[
INSTALLER
CODE
]+[
SLEEP
]
=
Answer WinLoad/BabyWare Software:
Will force the console to answer an incoming call
from the monitoring station that is using the WinLoad/BabyWare software.
[
ENTER
]+[
INSTALLER
CODE
]+[
BYP
]
=
Call WinLoad Software:
Will dial the PC telephone number programmed in section
[915]
in
order to initiate communication with a computer using the WinLoad software.
[
ENTER
]+[
INSTALLER
CODE
]+[
TBL
]
=
Installer Test Mode:
The installer test mode will allow you to perform walk tests where the
siren will squawk to indicate opened zones. Press the
[
TBL
]
key again to exit.
14.9
Daylight Savings Time
Section
[730]
: General Zone Options 2
Option
[1]
OFF = Daylight Savings Time Disabled (default)
Option
[1]
ON = Daylight Savings Time Enabled
With section
[730]
option
[1]
ON, the panel adjusts the system’s clock (time) for daylight savings changes. At 2:00AM on the
second Sunday of a full weekend in March, the control panel will add one hour to the programmed time (clock). At 2:00 AM on the
first Sunday of a full weekend in November, the control panel will subtract one hour from the programmed time (clock). By default,
when section
[730]
is set at 18, the time is set for the US, Canada etc. For other countries see Daylight Savings Programming in
the programming guide
and set the country code in section
[731]
.
14.10 Customized Daylight Saving Programming
In addition to using the default Daylight Saving Time (DST) settings in section
[731],
you can also set a customized DST. Set
section
[732]
for the DST starting period and
[733]
for the DST ending period. Both sections recognize 5 different entries of 2
digits each. All entries must be assigned in this respective order:
Country Code List (Default = bold)
00 = US, Canada, Mexico, St.Johns, Bahamas, Turks and
Caicos
01 = Cuba
02 = Brazil
03 = Chile
04 = Falklands
05 = Paraguay
06 = European Union, UK, and Greenland
07 = Russia and most states of the former USSR
08 = Australia- South Australia, Victoria, Australian Capital
Territory, New South Wales
09 = Lord Howe Island- Tasmania
10 = New Zealand, Chatham
11 = Tonga
12 = Iraq and Syria
13 = Israel
14 = Lebanon, Kirgizstan
15 = Palestine
16 = Egypt
17 = Namibia
18 = USA, Canada (New Daylight Saving Time for 2007)
19 = New Zealand (New Daylight Saving Time for 2007)
Months
01 to 12
01 = January
*If the day is set at 00, the DST will automatically change on
the programmed country code listed above.
Date
01 to 31
01 = First day of the month
Day
00 to 07
00 = Default*, 01 = Sunday
Hours
00 to 23
00 = Midnight
Minutes
00 to 59
00 = 60 minutes or 1 hour
Section Data
Description
[732]
__/__/__/__/__/__/__/__/__/__/
Daylight Savings Time Starting Period
[733]
__/__/__/__/__/__/__/__/__/__/
Daylight Savings Time Ending Period