Magellan / Spectra SP
51
12.25 Power Failure Report Delay
Section
[839]
001 to 255 minutes, Default = 15 minutes
The control panel will transmit the AC Failure report code programmed in section
[865]
after the Power Failure Report Delay
period has elapsed.
12.26 Report System Disarming
Section
[801]
: Arming /Disarming Options
Option
[1]
OFF = Always Report Disarming
Option
[1]
ON = Report Disarming Only After Alarm (default)
With option
[1]
OFF, the control panel will send the Disarming report codes (see
Special Disarming Report Codes
on page 45) to
the monitoring station every time the system is disarmed. With option
[1]
ON, the control panel will send the Disarming report
codes to the monitoring station when the system is disarmed following an alarm.
12.27 Zone Restore Report Options
Section
[801]
: Zone Options
Option
[2]
OFF = Report On Bell Cut-Off (default)
Option
[2]
ON = Report On Zone Closure
With option
[2]
OFF, the panel will send the Zone Alarm Restore report codes to the monitoring station when the zone has
returned to normal and the Bell Cut-Off Timer has elapsed. With option
[2]
ON, the panel will send the Zone Alarm Restore report
codes to the monitoring station as soon as the zone returns to normal or when the system is disarmed.
12.28 Telephone Line Monitoring (TLM)
When enabled, the system verifies the existence of a telephone line once every second. A line test failure occurs when the TLM
detects less than 3 volts for the period defined by the TLM Fail Timer. If the line test fails, the control panel’s
STATUS
LED flashes
and generates one or more conditions as defined by the TLM settings below. These will be restored when the control panel
detects the telephone line again. Please note that when the dialer detects an incoming call, the TLM test will stop for 1 minute.
Section
[800]
: Dialer Options
[1]
OFF /
[2]
OFF:
TLM Disabled
[1]
OFF /
[2]
ON:
Trouble Only
Upon line test failure, a TLM Trouble will appear in the keypad’s trouble display (see
Trouble Display
on page 60).
[1]
ON /
[2]
OFF:
Audible
Alarm If System Armed
Upon line test failure, a TLM Trouble will appear in the keypad’s trouble display (see
Trouble Display
on page 60) and if the
system is armed, the control panel will generate an audible alarm.
[1]
ON /
[2]
ON:
Silent Alarm Becomes Audible
Upon line test failure, a TLM Trouble will appear in the keypad’s trouble display (see
Trouble Display
on page 60) and causes a
silent zone or silent panic alarm to switch to audible.
12.28.1 TLM Fail Timer
Section
[830]
016 to 255 x 2 seconds, Default = 32 seconds
If TLM does not detect the existence of a telephone line for the duration of this period, the control panel will generate
the condition(s) defined by the TLM options.
12.29 Pager Reporting Delay
Section
[834]
: Communication Timers
000 to 255 seconds, Default = 20 seconds
When using the Pager Reporting Format, the control panel will wait for the Pager Delay period before transmitting the report
codes. This is to allow time for the pager system to provide a dial tone or to bypass the “welcome” message before sending data.
12.30 Pager Reporting Message Repetition
Section
[835]
: Communication Timers
000 to 255 times, Max. 10, Default = 3
When using the Pager Reporting Format, the control panel will repeatedly send the report codes to the pager until the
transmission has been acknowledged.