9.6.1 Maximum Dialing Attempts
Section [257]: 001-255
The number (000=8; 001-255) programmed into
section
[257]
determines how many times the control
panel will dial the same central station telephone
number before proceeding to the next number. Also
refer to section 9.6.3.
9.6.2 Delay Between Dialing Attempts
Section [258]: 001-255 seconds
This delay will determine the amount of time the
control panel will wait between dialing attempts. This
delay can be set from 001 to 255 seconds (000 = 20
seconds).
9.6.3 Alternate Backup Option
Section [522]: Option [6]
With option
[6]
enabled in section
[522]
, the control
panel will dial the selected back-up telephone
number after every failed attempt to contact a central
station telephone number. Otherwise (option [6] off),
the control panel will only dial the back-up telephone
number after the
Maximum Dialing Attempts
(see
section 9.6.1) to one central station telephone
number have failed.
9.7
R
ECENT
C
LOSE
D
ELAY
Section [219]: 000-255 seconds
If after having armed the system, an alarm is
generated within the period (000-255 seconds)
programmed into section
[219]
, the control panel will
transmit the recent close report code programmed
into section
[663]
.
9.8 A
UTO
T
EST
R
EPORT
Sections [261] & [270]
The control panel will transmit the test report code
programmed into section
[701]
after the number of
days (000-255) programmed into section
[261]
has
elapsed and at the time (00:00 to 23:59) programmed
into section
[270]
.
9.8.1 Hourly Test Transmission
Section [522]: Option [3]
Alternatively, the control panel can transmit the test
report code programmed into section
[701]
every
hour. Turn off option [3] to disable this feature.
Program the minute of each hour it sends the test
report into section
[270]
.
9.9 P
OWER
F
AIL
R
EPORT
D
ELAY
Section [260]: 001-255 minutes
The control panel will delay transmission of the “AC
Failure” report code programmed into section
[690]
by the period (000-255 minutes) programmed into
section
[260]
.
9.10 D
ISARM
R
EPORTING
O
PTIONS
Sections [506], [510], [514], [518]: Option [7]
As the control panel can enable the Disarming
Reporting Options for each individual partition, select
the section that corresponds to the desired partition
and turn option [7] on or off to set the desired option.
Option [7]
ON
–
R
EPORT ON
D
ISARM
A
FTER
A
LARM
O
NLY
The Digiplex Control Panel will send
Disarming Report
Codes
(see section 9.2.3) to the central station only
when the system is disarmed following an alarm.
OFF
–
R
EPORT ON
D
ISARM
The Digiplex Control Panel will send the
Disarming
Report Codes
(see section 9.2.3) to the central
station whenever a partition is disarmed.
9.11 Z
ONE
R
ESTORE
R
EPORT
O
PTIONS
Section [522]: Option [8]
ON
–
R
EPORT ON
Z
ONE
C
LOSURE
The control panel will send the “Zone Alarm
Restore” report codes (see section 9.2.5) to the
central station as soon as the zone returns to
normal (zone closure) or upon disarming
OFF
–
R
EPORT ON
B
ELL
C
UT
-O
FF
The control panel will send the zone alarm restore
report codes (see section 9.2.5) to the central station
when the
Bell Cut-Off Timer
has elapsed or when
the alarm has been cancelled (see section 8.2).
Summary of Contents for Digiplex
Page 1: ...Digiplex Control Panel Reference Installation Manual ...
Page 8: ... 7 ...
Page 54: ......