- 14 -
4.4.2 Duress
Sections [802] to [864] – Option [3]
When a user is forced to arm or disarm their system,
entering a
Duress
enabled
User Access Code
(option
[3] on) will arm or disarm the system and, if
programmed, will immediately transmit a silent alert
to the Central Station.
4.4.3 Bypass Programming
Sections [802] to [864] – Option [4]
The
User Access Code
with option [4] enabled can
program bypass entries as described in section 14.
4.4.4 Arm Only
Sections [802] to [864] – Option [5]
The
User Access Code
with option [5] enabled can
arm assigned partitions but can not disarm any
partitions. The type of arming is determined by the
other
User Options
selected. Please note that with
the
Arm Only
option, the user who just armed the
system can cancel arming by re-entering the same
User Access Code
during the
Exit Delay
.
4.4.5 Stay & Instant Arming
Sections [802] to [864] – Option [6]
The
User Access Code
with option [6] enabled, can
Stay Arm
or
Instant Arm
(see section 14) assigned
partitions.
4.4.6 Force Arming
Sections [802] to [864] - Option [7]
The
User Access Code
with option [7] enabled will be
able
to Force
arm assigned partitions as described in
section 14.
4.4.7 User Menu Access Conditions
Sections [802] to [864] - Option [8]
This feature will govern which partitions users have
access to when entering their access codes. With
option
[8] on
, the control panel will grant access to all
partitions assigned to the
User Access Code
. With
option
[8] off
, the control panel will only grant access
to partitions that have been assigned to both the
User Access Code
and the keypad.
4.5 U
SER
P
ARTITION
A
SSIGNMENT
Sections [802] to [864] – Options [1] to [4]
Each of the 63
User Access Codes
can be assigned
to one or more partitions. A user can only arm, disarm
and view status of assigned partitions. Select one or
more of the partitions for each
User Access Code
as shown in figure 4.1. The
System Master Code
or
a user with the
Master Feature
enabled can also
program the
User Partition Assignment
using a
different method of programming (see section 14).
User Options
Feature Select
Programming
Key-in
[
SECTION
]
User Code Options
[1] [2] Feature
off off
Master Feature Disabled
off on
Master Feature Disabled
on off
User can program access codes
on on
User can program access
codes, options & assignment
[3]
Duress
[6]
Stay & Instant
[4]
Bypass
[7]
Force
[5]
Arm only
[8]
Main Menu Access
*Note: all users can regular arm.
User Code Partition Assignment
[1]
User Code Has Access to Partition 1
[2]
User Code Has Access to Partition 2
[3]
User Code Has Access to Partition 3
[4]
User Code Has Access to Partition 4
User Partition
Assignment
Feature Select
Programming
Figure 4.1 - Programming User Parameters
Key in the
[
INSTALLER
CODE
]
Where sections
[802]
to
[864]
represent
User Access Codes
002 to 064.
U s i n g t h e m e t h o d d e s c r i b e d b e l o w , t h e I n s t a l l e r c a n
program the User Code Options and User Code Partition
Assignment but can not program any User Access Codes.
Press and hold
the
[0]
key
Press the
[
p
]
key
Press
[
ENTER
]
or the
[
p
]
key to
save and go to the next section.
4.6 M
ULTIPLE
A
CTION
F
EATURE
Section [504] – Option [1]
By enabling option
[1]
in section
[504]
, users will
remain in the
User Menu
after entering their access
code. This allows users to perform more than one
action without having to re-enter their access code.
With option
[1] off
in section
[504]
, the control
panel will exit the
User Menu
after every action.