Post-Installation Checks and Testing
Post-Installation Testing
46
ACS-1E and ACS-1EUL Install and Service Manual
Ver 2
4.2.3 ACS-1EUL Controller Tests
Power Indicator LED
Power Switch
SW4
ACS1E.UL Main
Board
Ethernet
Connection
+3 VO LTS
ETHERNET JACK
SW3
SW2
Second Reader Board Socket
1
2
3 4
5
6
CPU
4
1
2
3
9
10
1
2
3
6
1
2
3
7
1
2
3
4
5
6
8
I/O Relay
Board Socket
11
12
13
14
15
RTC Holdup
Battery Cell
16
Multi-Media Reader (MMR)
or
SkimGard Reader & Piezo
Buzzer
Wiring Map (TB6)
1 – RED (+8.5 VDC)
5 – YELLOW (Buz +)
2 – BLUE (–RS485)
6 – BRO WN (Buz –)
3 – GREEN (+RS485)
4 – BLACK (GND)
ACS1E.UL Main Board Legend
1
Box Tamper Input
For a
normally-open
(NO) plunger switch.
Switch is
closed
when panel box is shut.
2
Door Override
For a
normally-closed
(NC) switch. Function is
“looped out” (shorted) when not used.
3
Exit Switch Input
For a
normally-closed
(NC) switch.
(Input state
may be reversed using ACS Enterprise.)
4
Door-Sense Input
For a
normally-open
(NC) switch.
(Jumper header, JP1, to reverse INPUT state.)
5
6
Output #1
Assignable Relay (K3)
Wiring Map (TB10):
1 – COM
2 – NC
3 - NO
Output #2
Assignable Relay (K2)
Wiring Map (TB9):
1 – COM
2 – NC
3 - NO
7
Door Control Relay
(K1)
Wiring Map (TB8)
1 – COM1
4 – COM2
2 – NC1
5 – NC2
3 – NO1
6 – NO2
8
Power Supply Input
(TB1) Regulated 12 Volts DC (Reg.) at 1500 mA
(minimum).
10
11
RS232 Serial Input
Header Comm Port
(J4) For direct serial communications. (“Back-
door” connection for ethernet information.)
Door Sense Input
State-Select Header
(J1) Jumper IN = Input is
normally-closed
(NC)
Jumper
OUT =
Input is
normally-open
(NO)
12
Diagnostics Header
13
(JP5) Jumpering JP5 and restarting the Main
Board invokes Diagnostic Mode. (May not be
present in recent firmware versions.)
14
Reader Serial Number
Learning Jumper (JP3)
(1.) Header pins must be shorted mo mentarily
when a card read er is first in stalled or replaced.
(2.) A failure to do so will result in a “TAMPER”
in dication on the Main B oard and the po ssib le
activatio n of Outpu ts 1 and 2 if th ey h ave b een
assigned to the Tamp er alert.
Card Reader Alert
LED Indicators
Three LEDs are assig ned to indicate d etection of
three types of intentional card read er interference
or mischief:
(1) Tamper (2) Skim (Overlay) (3) Cable-Cut
15
16
Main Board Activity
Indicator Array
Array of ten LEDs indicate normal firmware
operation or two boot-loader states. (Top LED
indicates successful network connectivity.)
MAIN BOARD PUSH-BUTTONS
SW2
SW3
SW4
RS232 SERIAL MODE SELECT
MAINTENANCE MODE SELECT
SYSTEM RESET
Figure 3: ACS-1EUL Controller