AT-UHD-CLSO-601
28
WebGUI
System Settings
Display Auto Power
- Enable to send the programmed command to the display to turn on or off when detecting or
losing A/V signals.
Auto power off timer
- Sets the period of time between the loss of A/V signal and when the display off command
is sent. Default is 15 seconds and can be adjusted from 5 seconds to 1 hour.
Lamp cool down timer (Sec.)
- Sets the time between when projector lamp has been turned off to when it can
receive new commands. Default is 10 seconds and can be adjusted from 10 seconds to 300 seconds.
Display Warm-Up Timer (Sec.)
- Sets the time between when the projector lamp has been turned on to when it can
receive new commands. Default is 10 seconds and can be adjusted from 10 seconds to 300 seconds.
Control Type
- By default, CEC is selected for control of the display. IP and RS-232 can also be selected. When IP
or RS-232 are selected, more fields are available.
TCP/IP Settings of Controlled Device
(only available when IP is selected)
IP Mode
- Toggle telnet login mode between Non-Login and Login. If set to Login, a username and password
will be required to control the controlled device via TCP/IP.
IP Address -
Sets to the IP of the controlled device/display.
Telnet Port
- Set the telnet port of the controlled device for control. Default is 23.
Username & Password -
Sets the username and password that is required when login mode is enabled.