PD42-1270 TMCL
™
Firmware Manual • Firmware Version V1.00 | Document Revision V1.0 • 2017-Mar-02
65 / 91
Number
Axis Parameter
Description
Range [Units]
Default
Access
255
Unit mode
Units of velocity and acceleration/de-
celeration settings
0 - internal units of TMC5130
1 - pps for velocity and pps/s for ac-
celeration
0
. . .
1
1
RW
Table 11: All PD42-1270 Axis 0 Parameters