Number
Axis Parameter
Description
Range [Units]
Default
Access
163
Constant TOff
Mode
Selection of the chopper mode.
0 - spread cycle
1 - classic constant off time
0
. . .
1
0
RW
164
Disable fast
decay
comparator
See parameter 163. For "classic const.
off time", setting this parameter to "1"
will disable current comparator usage
for termination of fast decay cycle.
0 - enable comparator
1 - disable comparator
0
. . .
1
0
RW
165
Chopper
hysteresis end /
fast decay time
See parameter 163. For "spread cy-
cle" chopper mode this parameter
will set / return the hysteresis end set-
ting (hysteresis end value after a num-
ber of decrements). For "classic const.
off time" chopper mode this param-
eter will set / return the fast decay
time.
0
. . .
15
0
RW
166
Chopper
hysteresis start
/ sine wave
offset
See parameter 163. For "spread cy-
cle" chopper mode this parameter
will set / return the Hysteresis start
setting (please note that this value is
an offset to the hysteresis end value).
For "classic const. off time" chopper
mode this parameter will set / return
the sine wave offset.
0
. . .
8
0
RW
167
Chopper off
time
The off time setting controls the mini-
mum chopper frequency. An off time
within the range of 5us to 20us will
fit. Off time setting for constant t Off
chopper: NCLK = 12 + 32 tOFF (Mini-
mum is 64 clocks) Setting this param-
eter to zero completely disables all
driver transistors and the motor can
freewheel.
0
. . .
15
0
RW
168
smartEnergy
current
minimum
(SEIMIN)
Sets the lower motor current limit
for coolStep operation by scaling the
maximum current (see axis parame-
ter 6) value.
0 - 1/2 of CS
1 - 1/4 of CS
0
. . .
1
0
RW
169
smartEnergy
current down
step
Sets the number of stallGuard2 read-
ings above the upper threshold nec-
essary for each current decrement
of the motor current.
Number of
stallGuard2 measurements per decre-
ment: Scaling: 0. . . 3: 32, 8, 2, 1. 0:
slow decrement, 3: fast decrement
0
. . .
3
0
RW