PD42-1270 TMCL
™
Firmware Manual • Firmware Version V1.00 | Document Revision V1.0 • 2017-Mar-02
14 / 91
Command
Number
Parameter
Description
CCO
32
<coordinate number>, <motor num-
ber>
Capture coordinate
CALCX
33
<operation>
Process accumulator and X-register
AAP
34
<parameter>, <motor number>
Accumulator to axis parameter
AGP
35
<parameter>, <bank number>
Accumulator to global parameter
CLE
36
<flag>
Clear an error flag
ACO
39
<coordinate number>, <motor num-
ber>
Accu to coordinate
Table 5: Overview of all TMCL Commands
3.5
TMCL Commands by Subject
3.5.1
Parameter Commands
These commands are used to set, read and store axis parameters or global parameters. Axis parameters
can be set independently for each axis, whereas global parameters control the behavior of the module
itself. These commands can also be used in direct mode and in standalone mode.
Parameter Commands
Mnemonic
Command number
Meaning
SAP
5
Set axis parameter
GAP
6
Get axis parameter
STAP
7
Store axis parameter
RSAP
8
Restore axis parameter
SGP
9
Set global parameter
GGP
10
Get global parameter
STGP
11
Store global parameter
RSGP
12
Restore global parameter
Table 6: Parameter Commands
3.5.2
Branch Commands
These commands are used to control the program flow (loops, conditions, jumps etc.). Using them in direct
mode does not make sense. They are intended for standalone mode only.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at
www.trinamic.com
Read entire documentation.