PD42-1270 TMCL
™
Firmware Manual • Firmware Version V1.00 | Document Revision V1.0 • 2017-Mar-02
73 / 91
left limit / end / stop switch
L
R
start
stop
: reference search speed (axis parameter 194)
: reference switch speed (axis parameter 195)
Home
home switch
Figure 7: Reference search Mode 5
7.1.6
Mode 6
Reference search mode 6 searches the home switch in positive direction. The search direction will be
reversed if the left limit switch is reached. This is shown in figure
8
.
Add 128 to the mode number (i.e. set axis parameter #193 to 130) to reverse the polarity of the home
switch input.
L
R
right limit / end / stop switch
: reference search speed (axis parameter 194)
: reference switch speed (axis parameter 195)
start
stop
home switch
Figure 8: Reference search Mode 6
7.1.7
Mode 7
Reference search mode 7 searches the home switch in positive direction, ignoring the limit switch inputs.
It is recommende mainly for use with a circular axis. The exact middle of the switch will be found and used
as the zero point. Figure
9
illustrates this.
Add 128 to the mode number (i.e. set axis parameter #193 to 131) to reverse the polarity of the home
switch input.
©2017 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.