34
Item
■
Alarm Operation
When the WV-CU360C receives an alarm signal from a sys-
tem unit, the alarm indicator on the controller blinks.
The alarm indicator changes from blinking to steady light
when the alarm is automatically reset.
The camera number [---] appears in the camera section of
the LED display.
●
Alarm Reset
1. Press the
ALM RESET/ALM RECALL
button.
The alarm indicator on the controller goes off.
Notes:
• Alarm reset operations including auto reset are
applied to all system units, not to a selected one.
• Alarm reset mode differs depending on the system
unit connected to the WV-CU360C.
• Confirm that the SHIFT button is released.
●
Alarm Suspension
The alarm suspension mode is activated or deactivated.
Use this function when you do not want to be disturbed by
alarm input as for example during setup operations.
1. Press the
ALM SUSPEND
button. The
ALM SUSPEND
indicator lights up.
Alarm input is ignored while the indicator is lit.
ALM RESET
ALM RECALL
ALM SUSPEND
2. To cancel alarm suspension, press the
ALM SUSPEND
button again.
Note:
The alarm suspension is applied to all system
units, not to a selected one.
●
Alarm Recall
The alarm event log is recalled and displayed on the moni-
tor.
1. Select the desired system unit and monitor.
2. Press the
ALM RESET/ALM RECALL
button while the
SHIFT
indicator is lit. The
ALM RECALL
indicator lights
up. The alarm log appears on the monitor.
3. To cancel the alarm recall function, press the
ALM
RESET/ALM RECALL
button while the
SHIFT
indicator
is lit.
ALM SUSPEND
ALM RESET
ALM RECALL
SHIFT
Controller Operation
Note
Copy to DVD
Copy Cancel
DVD Copy Record Display
Equal to EL-ZOOM
SHIFT
SETUP
FUNCTION
SHIFT
SETUP
FUNCTION
SHIFT
SETUP
FUNCTION