Default:
Off
[Terminal alarm 3]
Select an action to be taken when a terminal alarm 3 is detected from the following.
•
Off:
Does not take any action even when a terminal alarm 3 is detected.
•
1-64
SW395
SC385
SC384
:
When the registered preset position is selected, the camera will move
to the selected preset position when a terminal alarm 3 is detected.
•
Auto track
SW395
SC385
:
When a terminal alarm 3 is detected, the camera will start the auto tracking.
•
1-256
SW396
SC386
:
If a previously registered preset position is selected, when a terminal alarm 3 is
detected, the camera will move to that position.
•
Auto track
SW396
SC386
:
When a terminal alarm 3 is detected, the camera will start the auto tracking.
•
Patrol 3
SW396
SC386
:
When a terminal alarm 3 is detected, the camera will start the patrol.
* If Patrol 3 is not registered it is not displayed on the screen.
•
Default:
Off
[VMD alarm]
Select an action to be taken when a VMD alarm is detected from the following.
•
Off:
Does not take any action even when a VMD alarm is detected.
•
1-64
SW395
SC385
SC384
:
When the registered preset position is selected, the camera will move
to the selected preset position when a VMD alarm is detected.
•
Auto track
SW395
SC385
:
When a VMD alarm is detected, the camera will start the auto tracking.
•
1-256
SW396
SC386
:
If a previously registered preset position is selected, when a terminal alarm 1 is
detected, the camera will move to that position.
•
Auto track
SW396
SC386
:
When a VMD alarm is detected, the camera will start the auto tracking.
•
Patrol 1
SW396
SC386
:
When a VMD alarm is detected, the camera will start the patrol.
* If Patrol 1 is not registered it is not displayed on the screen.
•
Default:
Off
[Command alarm]
Select an action to be taken when a command alarm is detected from the following.
•
Off:
Does not take any action even when a command alarm is detected.
•
1-64
SW395
SC385
SC384
:
When the registered preset position is selected, the camera will move
to the selected preset position when a command alarm is detected.
•
Auto track
SW395
SC385
:
When a command alarm is detected, the camera will start the auto tracking.
•
1-256
SW396
SC386
:
If a previously registered preset position is selected, when a terminal alarm 1 is
detected, the camera will move to that position.
•
Auto track
SW396
SC386
:
When a command alarm is detected, the camera will start the auto tracking.
•
Patrol 1
SW396
SC386
:
When a command alarm is detected, the camera will start the patrol.
* If Patrol 1 is not registered it is not displayed on the screen.
•
Preset per sender
SW396
SC386
:
By registering the sender's address for the command alarm and
the preset position for that address, the camera will move to the preset position when an alarm is detected
from the command alarm.
Click “Preset per sender >>” to open a separate window for setting preset positions for alarms.
(
®
page 132)
•
Default:
Off
13.2.1 Configure the settings relating to Preset per sender (“Preset
per sender” setup menu) (WV-SW396/WV-SC386)
On the [Alarm] tab (
®
page 130), click “Preset per sender >>” for “Command alarm”.
132
Operating Instructions
13 Configure the alarm settings [Alarm]