13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the
VMD area settings, and the alarm occurrence notification can be configured on this page.
The “Alarm” page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
®
page 43, page 45)
The settings relating to the alarm can be configured in this section. Refer to page 133 and page 136 for further
information about the settings relating to the alarm images and the alarm output terminal.
Alarm
[Terminal 1]
Determine how to use terminal 1.
•
Off:
Not used.
•
Alarm input:
Receives alarms.
•
Black & white input:
Receives the black & white switchover input. (When the input is set to On, the black
& white mode is activated.)
SW396
SW395
SC386
SC385
•
Default:
Off
[Terminal 2]
Determine how to use terminal 2.
•
Off:
Not used.
•
Alarm input:
Receives alarms.
•
Alarm output:
Alarm output will be carried out according to the settings for “Alarm output terminal
setup” (
®
page 136).
•
Default:
Off
[Terminal 3]
Determine how to use terminal 3.
•
Off:
Not used.
Operating Instructions
129
13 Configure the alarm settings [Alarm]