![Panasonic WV-CS850 Operating Instructions Manual Download Page 45](http://html.mh-extra.com/html/panasonic/wv-cs850/wv-cs850_operating-instructions-manual_277858045.webp)
45
• The following steps of installation and connection should be taken by qualified service personnel or
system installers and should conform to all local codes.
• Make sure to switch the camera off before installation and connection.
• Do not install the camera near the air outlet of an air conditioner.
Camera Mounting Base
Camera
Camera Mounting
Base
Fixing Screw
Loosen and
Push
1
2
3
4
ON
1
2
3
4
ON
5
6
7
8
8-bit DIP SW
4-bit DIP SW
INSTALLATION
1. Disassembling the camera
(1) Loosen the fixing screw to separate the
camera mounting base and the camera.
Push up the screwdriver once before
removing the screw.
(2) Turn the camera mounting base ap-
proximately 15 degrees counter clock-
wise and remove the base from the
camera.
2. Setting the switches
There are two DIP switches on the camera:
an 8-bit switch and a 4-bit switch. The 8-bit
DIP switch is used in both ways to imple-
ment protocol selection and to specify the
unit number. The 4-bit DIP switch selects
termination ON/OFF and half/full duplex
selection for RS485 communications. Switch
settings are read in to the camera when the
power is turned on. Make sure to turn it off,
then turn it back on after changing the
switch settings. Switch positions and func-
tions are shown below.
RS485 Parameter Setup
The selected protocol, communication para-
meters, and set unit numbers are read into
the camera when power is switched on.
1. Set the switch according to the function
shown in the table.
2. Switch off the camera.
3. Switch on the camera to read in the
changed switch settings.
Note:
The changed communication
parameters are displayed on the
RS485 SETUP menu after the cam-
era is switched on.
Precautions
15
°
Turn 15
°
Then
Camera
Mounting Base
Remove
from the
Camera
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
Switch Position
Protcol Selection
Panasonic’s conventional
Panasonic’s NEW generation
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
1
2
3
4
ON
5
6
7
8
Switch Position
Paramater Selection
BAUD RATE
1
1
1
NONE
NONE
NONE
8
8
8
19 200
9 600
4 800
DATA BIT
PARITY
CHECK
STOP
BIT
Intelligent Security & Fire