![Panasonic WV-CS850 Operating Instructions Manual Download Page 44](http://html.mh-extra.com/html/panasonic/wv-cs850/wv-cs850_operating-instructions-manual_277858044.webp)
44
ALARM DATA
Specifies alarm transmission mode depending on the protocol selected by the 8-bit DIP switch. Refer to
INSTALLATION for protocol selection.
For Panasonic’s conventional
POLLING:
Transmits the alarm data in response to requests from the controller.
AUTO 1:
Transmits the alarm data each time an alarm signal is received.
AUTO 2 (Default):
Transmits alarm data every 5 seconds.
For Panasonic’s NEW protocol (reserved for future use with connection to the personal computers)
OFF:
Transmits alarm data in response to requests from the controller.
0S:
Transmits alarm data each time an alarm signal is received.
1S:
Transmits alarm data every 1 second.
5S:
Transmits alarm data every 5 seconds.
DELAY TIME
Specifies the time to transmit the acknowledge request when communicating on a two-line connection.
(OFF, 10, 20, 40, 100 ms) Default : OFF.
This menu appears only when a two-line communication is used. Make sure to 100 ms when connecting
the camera with the WJ-FS616 Video Multiplexer in a 2-line communication system.
The settings become effective with the closing of the SET UP MENU.
Note:
Set the same parameters for the cameras, controllers and personal computers in an RS485 chain.