64
Setup items
■
Resolution
Select a resolution for images to be recorded from the
following.
FIELD:
Standard resolution (720 x 240)
FRAME 3D ON:
High resolution (720 x 480), with blur-
ring compensation
FRAME 3D OFF:
High resolution (720 x 480)
SIF:
Low resolution (360 x 240)
Important:
In the following cases, recording will not be per-
formed for around 4 seconds:
• When resolution is switched such as when a dif-
ferent resolution is set depending on different
time zones
• When the SETUP MENU is closed after chang-
ing the settings
■
Recording Rate and Image Quality for Each
Camera Channel
Perform the settings for the recording rate, image quali-
ty and recording duration for each camera channel (The
settings for recording duration can be performed only for
pre-event recording and post-event recording.).
OFF/0.1 ips/0.2 ips/0.3 ips/0.4 ips/0.5 ips/1 ips/2 ips/
3 ips/5 ips/6 ips/7.5 ips/10 ips/15 ips/30 ips/60 ips
Important:
• When the total of the recording rate of camera chan-
nels 1 - 16 is set to the maximum (60 ips when
FIELD is selected, 120 ips when SIF is selected),
the recording rate of two of the camera channels to
which the lowest and the second lowest recording
rates are set will be lower than the set recording
rate. (When the lowest recording rate is applied to
three of the camera channels this may happen to
two of the three channels.) In this case, the actual
recording duration may be longer than the set post-
event recording duration.
Notes:
• The total recording rates for each camera channel
must be the following values.
FRAME 3D ON/FRAME 3D OFF:
30 ips or less
FIELD:
60 ips or less
SIF:
120 ips or less
• Recording will be performed differently depending
on the status of a video input signal supply as fol-
lows:
The following are available for the image quality.
SFA/SFB:
Top quality (SUPER FINE)
FQA/FQB:
High quality (FINE)
NQA/NQB:
Standard quality (NORMAL)
EXA/EXB:
Low quality (EXTENDED)
**A is suitable for less dynamic images.
**B is suitable for more dynamic images.
The following are available for recording duration (only
pre-event recording and post-event recording).
1 - 10 s
(in 1 second intervals)
/20 s/30 s/1 - 10 min
(in
1 minute intervals)
/20-60 min
(in 10 minutes intervals)
MANUAL:
Recording duration will be as follows
depending on the event type.
• At a terminal alarm occurrence: During the sup-
ply of a signal
• At a video loss occurrence: During a video loss
occurrence
• At a command alarm: For 8 seconds
• At a motion detection: For 8 seconds
CONTINUE:
Recording will not stop unless the [ALARM
RESET] button on the front panel of the unit is
pressed or the [ALARM RESET] button in the status
display area is clicked.
Note:
MANUAL and CONTINUE are available only for
post-event recording.
When no video
input signal is sup-
plied at the start
time of recording
When the video
input signal supply
stopped during
recording
When the video input
signal supply
stopped during
recording is resumed
Manual
recording/
Schedule
recording
Recording will
not be per-
formed.
Recording will
be stopped.
Recording will
be resumed.
Event record-
ing
Recording will be
performed.
(A black screen
will be recorded.)
Recording will be
performed.
(A black screen
will be recorded.)
–