73
Configure the event action at a camera site alarm occurrence [Site
alarm]
Select the [Site alarm] tab on the "Event" page. (
+
Page 60)
The settings relating to event actions to be taken at a camera site alarm (
+
Operating Instructions (PDF)) occurrence can be con-
figured on this tab.
[Operation mode]
Select the settings for the operation mode. Refer to the
operating instructions (PDF) for further information about the
operation mode.
ADM (Activity Detection Mode):
Performs recording,
writes the event log, and moves the cameras to pre-
set positions at an event occurrence. Other event
actions will not be performed.
ALM (Alarm Mode):
Performs every event action
according to the settings.
OFF:
Performs only writing an event log. Other event
actions will not be performed.
Configure the following settings for each camera channel (1
to 16).
[Rec. cam.]
Select a camera channel (1 to 16) used for recording. When
"Off" is selected, recording will not be performed.
[Preset]
Select a preset position (1 to 256) to which the camera will
move at an alarm occurrence.
When the preset positions of two or more cameras have
been selected on the advanced setup page, "
∗∗∗
" is dis-
played and it is impossible to select the values.
[Output terminal]
Select a terminal (TRM1 to TRM16) to output the alarm sig-
nal.
Summary of Contents for WJ-HD716K