2-6. Extension Box :
VL-V703
2
Role of the VL-V703
Extend the number of Lobby Station. ( Original 3pcs. Max.
Up to 18pcs. )
Operation Environment : -10
℃
to 50
℃
Role/ Features / Installation
(1) Power indicator (POWER)
(2) Access indicator (ACCESS)
(3) Connection terminals for lobby station
(4) Power switch
(5) Cable release button for DC power supply cable
(6) Connection terminals for DC power supply
(7) Reset button (
・
)
Used when restarting the extension box.
(8) Function button (
・・
)
For internal use only.
Category
Meaning
POWER
(GREEN)
ACCESS
(RED)
Idle
Lit
Off
Call in progress
Lit
Lit
Error
DIP switch 4 or 6 or 7 or 8 is in the "on" position
Lit
Flashing
Normal
operation
AC
DC:24V
(11
)
Attached Power Supply Unit
Wiring run
Wire diameter
Max. length
Power supply unit
⇔
Lift controller
2 mm (12 AWG)
approx. 20 m
Power supply unit
⇔
AC power source
1.2 mm (17
AWG) No requirement
2 mm (12 AWG)
(Indoor use only)
(1)
(2)
(3)
(4) (5) (6)
(7)
(8)