Page 1: ...For EntriTech series hands free handset indoor monitors ...

Page 2: ...ech HF issue 1 Contents Indoor monitor controls 3 Specification connection details 4 Link setting for multiple monitor systems 5 Installation instruction 6 Wiring diagram 7 Two entrance system wiring 8 Operation 9 Note 10 ...

Page 3: ...n 1 TFT screen 8 Unlock button 2 Speaker 9 Talk button 3 Power in use indicator 10 Microphone 4 Door 1 calling indicator 11 Brightness 5 Door 2 calling indicator 12 Colour 6 Monitor button 13 Volume 7 Call button 14 Ring adjust 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Connection Plugs Jumpers ...

Page 4: ...ondition RH 95 non condensing Voltage DC14 5V Standby Current 50mA Working Current 7 600mA 4 400mA Mode Dual transmission Talking time 2 minutes Connection detail The main video monitor s are connected to the system by use of pre wire sockets Ve Ve J2 J1 J3 4 CN1 3 2 1 4 3 CN2 2 1 ...

Page 5: ...lls the indoor monitor the sounder on outdoor panel will also operate J2 linked amplifies the video signal If you connect 2 or more indoor monitors link the jumper J2 of the farthest monitor and remove the jumper J2 on the other monitors J3 linked Call button illuminated J3 J1 J2 J3 J1 J2 J3 J1 J2 J3 J1 J2 1ST MONITOR 2nd MONITOR 3rd MONITOR 4th MONITOR LINK LINK LINK ...

Page 6: ...alling 4 The wiring installation should be a minimum distance of 30cm away from any mains voltage cables 5 Check all connections prior to powering up Always switch off prior to working on the system Installation 1 Position the main unit in the required location 2 Use the bracket to mark the position of the holes 3 Use screws plugs to fix the bracket to the wall 4 Connect as shown in wiring diagram...

Page 7: ...d looms should be extended via a suitable junction box Extension cable should be of minimum diameter 0 5mm2 the maximum distance from an outdoor station to the farthest monitor distance should be 70m 2 Each Monitor should be connected parallel Maximum number of monitors is 4 The Power supply unit requires a 230vAC 50Hz supply which should be protected by a suitable fuse or MCB Connection Details 1...

Page 8: ...Page 8 of 10 EntriTech HF issue 1 Two entrance system ...

Page 9: ...button on other displays opens up a 3 way conversation The maximum talk time is 2 minutes The chimes will operate for 1 minute if left unanswered If a lock release is fitted pressing the Key button releases the lock To monitor the camera view without speech press the Monitor button if more than one outdoor station is fitted each time you press the Monitor button the display will cycle to the next ...

Page 10: ...it near magnetic sources such as TV s Do not install the unit in wet or humid environments Do not install the unit in hot environments or near sources of heat Do not drop or shake the unit Install it away from potential causes of damage Do not open the unit There are no user serviceable parts ...