63
4.1.9
Service Mode 9 (System Maintenance)
4.1.9.1
Overview
This Service Mode is used to maintain and/or update the firmware of the machine.
Use the following procedure for System Maintenance.
System Maintenance Table
Step
Operation or Unit Condition
LCD Display
1
Standby
2
Press “FUNCTION” and then “7”.
3
Press “MONITOR” four times, then press “*”.
4
Press “9”.
5
Press “START” to update the firmware.
Enter No. or press ”/\” or “\/“ to select the maintenance
to be performed.
Ex: Enter “2”.
6
Press “START” and “SET”.
7
After the backup is completed, repeat step 5 through 6
to request an operation.
8
Press “STOP” to return to standby.
No.
Maintenance Mode
Description
1
FIRMWARE UPDATE
Updates the firmware in the machine with the Master Firm-
ware Card.
2
FIRMWARE BACKUP
Creates a Backup Card of the machine’s firmware.
(A 2 MB or higher Flash Memory Card is required)
3
PARAMETER
RESTORE
Restores the parameters from the Backup Card into the
machine.
4
PARAMETER BACKUP Creates a Backup Card of the machine’s parameters.
(A 1 MB or higher Flash Memory Card is required)
5
PC
→
FLASH CARD
Creates a Master Firmware Card using the Firmware
Update Tool.
(A 2 MB or higher Flash Memory Card is required)
8
SEND RECEIVED FILE Transfers documents from memory to another fax machine
during a fatal printer error.
OCT-12-2001 15:00
00%
SET MODE (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
SYSTEM MAINT. (1-8)
1:FIRMWARE UPDATE
SYSTEM MAINT. (1-8)
2:FIRMWARE BACKUP
FIRMWARE BACKUP
* IN PROGRESS *
SERVICE MODE
ENTER NO. OR
OCT-12-2001 15:00
00%