33
Note 1: No. 070 LINE ERROR-Transmit condition of RTP/PIP or RTN/PIN
Note 2: No. 071 TOTAL ERROR-Transmit condition of RTP/PIP or RTN/PIN
Note 3:
The default setting of parameters depends on the destination’s specifications or regulations.
Print the Function Parameter List to confirm the default settings.
Note 4:
Continuous Polling (Station Mode)
This feature allows you to store or add documents into a polled file in memory.
To enable the Continuous Polling feature set Function Parameter No. 003 to "2:Station". The Program
Key [P8] will be assigned with the "Store-4-Polling" name automatically and cannot be changed.
To prepare the document(s) to be polled, simply place the document(s) on the ADF and then press the
Program Key [P8] to store or add the document(s) into a polled file.
(Note: If a regular polled file ([FUNCTION][3][2]) is stored in memory, the Program Key [P8] for
Continuous Polling will not be accepted.)
Continuous Polling (Hub Mode)
When the polling command is initiated, the machine will continuously poll documents from the remote
stations until it is interrupted by pressing "STOP".
Signal
Setting
1:128
2:256
3:512
4:1024
5:2048
6:Off
MCF/PIP
0-31
0-63
0-127
0-255
0-511
Always
RTP/PIP
32-63
64-127
128-255
256-511
512-1023
-
RTN/PIN
64-127
128-255
256-511
512-1023
1024-2047
-
Signal
Setting
1:5%
2:10%
3:15%
4:20%
MCF/PIP
0-2
0-4
0-7
0-9
RTP/PIP
3-4
5-9
8-14
10-19
RTN/PIN
5-
10-
15-
20-
Summary of Contents for UF 890 - Panafax B/W Laser