169
UF-7300/7200
UF-8300/8200
011 RX LEVEL
1 = -43 dBm
2 = -38 dBm
3 = -33 dBm
4 = -48 dBm
Selects the receiving sensitivity of -33/-38/-43/-48
dBm.
012 DTMF LEVEL
00 = 0 dBm
~
15 = -15 dBm
Selects the DTMF output level, 0 to -15 dBm in 1
dBm steps.
013 G3 RX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 reception mode,
0dB, 4dB, 8dB or 12dB.
014 G3 TX EQL
1 = 0dB
2 = 4dB
3 = 8dB
4 = 12dB
Selects the cable equalizer for G3 transmission
mode, 0dB, 4dB, 8dB or 12dB.
015 ~
016
Not Used
017 TX START
2400 bps
4800 bps
7200 bps
9600 bps
TC7200 bps
TC9600 bps
12000 bps
14400 bps
Selects the transmission modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
(Press the
“ ”
,
“ ”
keys to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 32.
018 RX START
2400 bps
4800 bps
7200 bps
9600 bps
TC7200 bps
TC9600 bps
12000 bps
14400 bps
Selects the reception modem start speed, 14400/
12000/TC9600/TC7200/9600/7200/4800/2400 bps.
(Press the
“ ”
,
“ ”
keys to select the symbol rate.)
Note:
This parameter is applicable only when
communicating with regular G3 machines. When
communicating with Super G3 (V.34) machines,
use Parameter No. 33.
019 ITU-T V.34
1 = Off
2 = On
3 = Select
Selects whether the ITU-T V.34 is Off, On or Select.
Select:
Select whether the ITU-T V.34 is Off or On, when
entering Phone Book Dialing Numbers or Manual
Number Dialing.
020 ITU-T ECM
1 = Off (Invalid)
2 = On (Valid)
Select the ECM mode.
Note:
When communicating with V.34, the ECM mode
becomes effective automatically regardless of this
parameter setting.
021 EP TONE
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on V.29
mode.
(Used when Echo Suppression is disabled.)
On
: Add
Off
: Do not add
022 SIG. INTERVAL
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving signal
and the transmitting signal.
023 TCF CHECK
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
Function Parameter Table
No.
Parameter
Selections
Function